Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • ProductType 1002: Measure the MDT (mounting detection tool) and give the values R, X, Angle

  • ProductType 1: Measure the angle in a ROI (region of interest)

  • ProductType 0: Do nothing

To start a job do the following steps:

  1. stop the sensor from the actual job (CMD_STOP)

  2. put the plate material or MDT (depending on the job) inside the machine

  3. send the product parameters to the sensor (CMD_RECEIVE_PRODUCT_DATA)

  4. send the sensor parameters to the sensor (CMD_RECEIVE_SENSOR_DATA)

  5. receive the results (the camera sends results after every scan until you stop it)

  6. maybe ignore the first 5 - 10 angles, as they are not that accurate because of auto exposure adaption

Set the necessary step (parameter ID) with the STRING command:

...

It is possible, to send one, more or all parameters in one “STRING” command. Just terminate every parameter by Line Feed (0x0A) or NULL (0x00) or “\n”.

Infonote

Attention: Please take care, that you send the parameters to both sensors (front and back) by using the individual sensor IP.

...

The sensor parameters at: /etc/vcnano3dz-server/VC3DPar.txt
The product parameters at: /etc/vcnano3dz-server/ProdPar.txt

...