ProductType 1002: Measure the MDT (mounting detection tool) and give the values R, X, Angle
ProductType 1: Measure the angle in a ROI (region of interest)
ProductType 0: Do nothing
To start a job do the following steps:
stop the sensor from the actual job (CMD_STOP)
put the plate material or MDT (depending on the job) inside the machine
send the product parameters to the sensor (CMD_RECEIVE_PRODUCT_DATA)
send the sensor parameters to the sensor (CMD_RECEIVE_SENSOR_DATA)
receive the results (the camera sends results after every scan until you stop it)
maybe ignore the first 5 - 10 angles, as they are not that accurate because of auto exposure adaption
Set the necessary step (parameter ID) with the STRING command:
...
It is possible, to send one, more or all parameters in one “STRING” command. Just terminate every parameter by Line Feed (0x0A) or NULL (0x00) or “\n”.
Infonote |
---|
Attention: Please take care, that you send the parameters to both sensors (front and back) by using the individual sensor IP. |
...
The sensor parameters at: /etc/vcnano3dz-server/VC3DPar.txt
The product parameters at: /etc/vcnano3dz-server/ProdPar.txt
...