Signal | Description |
---|---|
INP 0 – INP 5 | PLC inputs. |
OUT 0 – OUT 3 | PLC outputs. |
Laser Enable | Hardware safety signal for the activation of the laser, must be set to high to enable |
TrigIn | External trigger for image capture. |
Trigger Enable | External signal to activate capturing, must be set to high for the complete capturing |
ENC A, ENC /A, ENC B, ENC /B, ENC Z | Encoder signals. |
TrigOut | External trigger output, only supported at OEM custom versions; Other versions |
...
Info |
---|
If the Laser Warden is used and no Laser Enable is given, the capture will be done nevertheless but without active laser. |
...
2.1.2 Electrical Specification: Camera Power Supply
...
2.1.3.1 Connection of PLC, Encoder inputs VC nano 3D-Z Series
...
2.1.3.2 Connection of PLC outputs VC nano 3D-Z Series
...
It is possible to connect the following encoder signals: ENC A, ENC /A, ENC B, ENC /B, ENC Z. There is no connection provided for signal ENC /Z.
...