Description

INP 0 – INP 5

PLC inputs.

OUT 0 – OUT 3

PLC outputs.

Laser Enable

Hardware safety signal for the activation of the laser, must be set to high to enable
the laser. It completely shuts down the power supply of the laser.
Feature depending on hardware option. Does not influence triggering.

TrigIn

External trigger for image capture.

Trigger Enable

External signal to activate capturing, must be set to high for the complete capturing
process. If signal is set to low, triggers will be blocked.

ENC A, ENC /A, ENC B, ENC /B, ENC Z

Encoder signals.

TrigOut

External trigger output, only supported at OEM custom versions; Other versions
will be inaccurate!

...

Info

If the Laser Warden is used and no Laser Enable is given, the capture will be done nevertheless but without active laser.

...

Image Added

2.1.2   Electrical Specification: Camera Power Supply

...

2.1.3.1   Connection of PLC, Encoder inputs VC nano 3D-Z Series

...

2.1.3.2   Connection of PLC outputs VC nano 3D-Z Series

...

It is possible to connect the following encoder signals: ENC A, ENC /A, ENC B, ENC /B, ENC Z. There is no connection provided for signal ENC /Z.

...