Attention: Please take care, if you make some sensor or product parameters adjustable, then send them also to the sensor (together with the “Necessary Parameter”). |
VC parameter name | Default | MinVal | MaxVal | Explanation |
---|---|---|---|---|
-Measure Mode- | 0 | 0 | 2 | 0=Both 1=Front |
Standard Parameters | ||||
NMZ | 3 | 0 | 40 | No measurement zone [mm] |
LML | 30 | 5 | 80 | Laser measure length [mm] |
Expert Parameters | ||||
-Front Sensor- | ||||
IP | x.x.x.x | IP address of sensor | ||
X | < 0 | Sensor mounting [mm] | ||
R | < 0 | Sensor mounting [mm] | ||
Angle | < 0 | Sensor mounting angle [°] | ||
-Back Sensor- | ||||
IP | x.x.x.x | IP address of sensor | ||
X | > 0 | Sensor mounting [mm] | ||
R | < 0 | Sensor mounting [mm] | ||
Angle | > 0 | Sensor mounting angle [°] | ||
AutoTriggerFPS | 50 | 10 | 400 | Frames per second [fps] |
ExposureMode | 1 | 0 | 3 | Exposure mode for image acquisition |
(LaserSelect) | 0 | 0 | 2 | Laser line method (useful 0 and 1) |
(ReflexionFilter) | -1 | -7 | 7 | Laser line detection filter mode |
(AutoShutterFilter) | 0 | 0 | 6 | Auto shutter mode where laser brightness is based on |
-Auto Detection of MDT- | These parameters are only used in ProductType 1002 | |||
J00_MDT_LenBC_MM | 73 | 10 | 200 | MDT length from reference base line to centre of Phi |
J00_MDT_LenBA_MM | 50 | 10 | 100 | MDT base width |
(J00_MDT_Phi_DEG) | 135 | 30 | 180 | MDT Detection Angle Phi |
(J00_MDT_LenLine0_MM) | 60 | 10 | 100 | MDT measure length of base part |
(J00_MDT_LenLine1_MM) | 60 | 10 | 100 | MDT measure length of top part |