5. Recommended Mounting Positions
5. Recommended Mounting Positions
You only need the standard sensor VC nano 3D Z 630 regular. For the large range of dies V6 – V200 we recommend the following mounting positions.
They are also available as portable versions:
VK000560 / VC PB-PMK (portable mounting kit) V6 - V70 / 30°
VK000562 / VC PB-PMK (portable mounting kit) V6 - V160 / 33°
VK000441 / VC PB-PMK (portable mounting kit) V60 - V200 / 26°
Please select the typical range you need. For smaller ranges you can put the sensor closer to the plate, which leads to a higher accuracy. Please refer to the chapter “Typical Accuracy”.
, multiple selections available,
Related content
4.1 Manual detection of mounting position
4.1 Manual detection of mounting position
Read with this
10. Communication Steps for Bending
10. Communication Steps for Bending
Read with this
8. Strain-gauges
8. Strain-gauges
Read with this
6. Typical Accuracy
6. Typical Accuracy
Read with this
10.3 Stop angle measurement
10.3 Stop angle measurement
Read with this
3. Sensor mounting
3. Sensor mounting
Read with this