Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

VC parameter name

Default

MinVal

MaxVal

Explanation

-Measure Mode-

0

0

2

0=Both 1=Front
2=Back Sensor for plate angle

Standard Parameters

NMZ

3

0

40

No measurement zone [mm]

LML

30

5

80

Laser measure length [mm]

Expert Parameters

-Front Sensor-

IP

x.x.x.x

IP address of sensor

X

< 0

Sensor mounting [mm]

R

< 0

Sensor mounting [mm]

Angle

< 0

Sensor mounting angle [°]

-Back Sensor-

IP

x.x.x.x

IP address of sensor

X

> 0

Sensor mounting [mm]

R

< 0

Sensor mounting [mm]

Angle

> 0

Sensor mounting angle [°]

AutoTriggerFPS

50

10

400

Frames per second [fps]
(>174 fps limit sensor area)

ExposureMode

1

0

3

Exposure mode for image acquisition
(useful 1 for standard and 3 for difficult materials)

(LaserSelect)

0

0

2

Laser line method (useful 0 and 1)

(ReflexionFilter)

-1

-7

7

Laser line detection filter mode
(useful -1 and 1)

(AutoShutterFilter)

0

0

6

Auto shutter mode where laser brightness is based on

-Auto Detection of MDT-

These parameters are only used in ProductType 1002

J00_MDT_LenBC_MM

73

10

200

MDT length from reference base line to centre of Phi

J00_MDT_LenBA_MM

50

10

100

MDT base width

(J00_MDT_Phi_DEG)

135

30

180

MDT Detection Angle Phi

(J00_MDT_LenLine0_MM)

60

10

100

MDT measure length of base part
(from centre of Phi)

(J00_MDT_LenLine1_MM)

60

10

100

MDT measure length of top part
(from centre of Phi)